Anatol V Sukhomlyn wrote:
-----BEGIN PGP SIGNED MESSAGE----- Hash: SHA1
Вот чего мне ответили из Comtrenda
Hello,
The current situation of the CT-520 after upgrade is staying at self-testing mode. It is caused by that "[M] Erase Machine Parameter" had been executed before. The only way to recover the CT-520 back to operation. Please press "y" immediately after "Start Self Tesing..." through console rate with 115200 bps. However, "[M] Erase Machine Parameter" is to erase MAC address of the CT-520, you need to reassign the MAC again after the CT-520 is back to operation. Here are the procedures for your situation.
(1). Please press "y" immediately after "Start Self Tesing..." through console rate with 115200 bps. The CT-520 change the state to operation. You could use the console with 9600 speed to check it out. (2). Re-assign MAC address of the CT-520. Press “a” key immediately after CT-520 power up to go to the debug mode. (3). Follow the last step specified in UPGRADE PROCEDURES, this time please execute "[M] Erase Machine Parameter". Reboot the CT-520 and key in the new MAC address 0030da0012ad for example.
(4). Please press "y" immediately after "Start Self Tesing..." through console rate with 115200 bps in order to get back to operation.
правда как его перевести в рабочий режим после перезагрузки пока не ясно ))((( жду от них продолжения ))
Ура ! Получилось ! Кто бы мог подумать что надо "y" нажимать ! В общем обобщая надо нажимать "ya" на скорости 115200, потом [M] Erase Machine Parameter", потом "O" чтоб выключить Self Testing mode. Потом в reboot и переключаемся на 9600 и все как обычно... Добрый человек, какое пиво ты любишь ? -- Biryukov Andrei ElVisti Information Center, Kiev, Ukraine. E-mail amb@visti.net =================================================================== uanog mailing list. To Unsubscribe: send mail to majordomo@uanog.kiev.ua with "unsubscribe uanog" in the body of the message