1 Raw_Read_Error_Rate 0x000b 099 099 016 Pre-fail Always - 3 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 25
Может, и проживет еще лет 10. А может и умрет завтра. Если под нагрузкой,
скажем, за час, эти параметры не растут, то беспокоится особо не о чем.
Остальные параметры в норме.
2016-03-11 23:54 GMT+02:00 Volodymyr Litovka
Уважаемые коллеги,
как выполагете, если S.M.A.R.T. status выводит такое -
SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 099 099 016 Pre-fail Always - 3 2 Throughput_Performance 0x0005 132 132 054 Pre-fail Offline - 142 3 Spin_Up_Time 0x0007 112 112 024 Pre-fail Always - 342 (Average 341) 4 Start_Stop_Count 0x0012 098 098 000 Old_age Always - 11844 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 25 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 131 131 020 Pre-fail Offline - 29 9 Power_On_Hours 0x0012 095 095 000 Old_age Always - 38881 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 302 192 Power-Off_Retract_Count 0x0032 089 089 000 Old_age Always - 13510 193 Load_Cycle_Count 0x0012 089 089 000 Old_age Always - 13510 194 Temperature_Celsius 0x0002 162 162 000 Old_age Always - 37 (Min/Max 18/50) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 41 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1 No Errors Logged
SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 25105 - # 2 Short offline Completed without error 00% 25102 - # 3 Short offline Completed without error 00% 19112 -
============== SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always - 0 2 Throughput_Performance 0x0005 132 132 054 Pre-fail Offline - 140 3 Spin_Up_Time 0x0007 114 114 024 Pre-fail Always - 336 (Average 337) 4 Start_Stop_Count 0x0012 098 098 000 Old_age Always - 10449 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 1 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 129 129 020 Pre-fail Offline - 30 9 Power_On_Hours 0x0012 095 095 000 Old_age Always - 38018 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 304 192 Power-Off_Retract_Count 0x0032 091 091 000 Old_age Always - 11678 193 Load_Cycle_Count 0x0012 091 091 000 Old_age Always - 11678 194 Temperature_Celsius 0x0002 166 166 000 Old_age Always - 36 (Min/Max 16/49) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0
SMART Error Log Version: 1 No Errors Logged
SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Extended offline Completed without error 00% 24238 - # 2 Short offline Completed without error 00% 24236 - # 3 Short offline Completed without error 00% 18951 -
то это мне вот прямо сейчас в магазин за жесткими дисками бежать или подождать утра? :)
-- Volodymyr Litovka "Vision without Execution is Hallucination." -- Thomas Edison