Hello ! У нас примерно так (только там не EWSD а чудо из Уфы) controller E1 4 framing NO-CRC4 clock source line primary ds0-group 0 timeslots 1-15,17-31 type r2-digital r2-compelled ani cas-custom 0 unused-abcd 0 0 0 0 country easteurope debounce-time 10 release-guard-time 150 seizure-ack-time 2 answer-signal group-a 6 dnis-digits min 1 max 1 ani-digits min 0 max 7 answer-guard-time 40 On Wed, Dec 07, 2005 at 05:27:34PM +0200, Andrey Nikolaev wrote:
подскажите рабочую конфигурацию для AS5300 включения E1 потока с R2 сигнализацией в ESWD.
-- S/Y, Alexander, MD, nic-hdl: AJP1-UANIC =================================================================== uanog mailing list. To Unsubscribe: send mail to majordomo@uanog.kiev.ua with "unsubscribe uanog" in the body of the message